Operation ECA 450
30 Instruction 0024-9400
4. Use ∧∨ keys to place cursor next to “Enter”; then press ENTER to display
the Primary Air Temperature screen.
Primary Air
Measure
ª Enter
5. Press ENTER to move the cursor into the temperature data field; then use
the
∧, ∨ , <, and > keys as necessary to enter the temperature value that
was measured in Step 1. Note that leading zeros should be entered as
either a numerical 0 or a blank space.
For example: a primary air temperature of 35.5 °F should be entered as
035.5 in the display.
Primary Air
Temperature
035.5 °F
6. Press ENTER to save the displayed temperature value in the analyzer’s
temperature memory buffer and return to the Setup List screen.
Note: The temperature memory buffer is cleared when the analyzer is
turned off, or when the T-AIR thermocouple is installed after the entered
number is saved.
2.14.4 Internal Temperature Sensor Method
If a thermocouple is not plugged into the T-AIR connector, and there is no
data stored in the temperature memory buffer, then the analyzer defaults to
the instrument’s internal temperature as measured on the main printed
circuit board.
When viewing the T-AIR value on the Combustion Test HOLD/RUN screen,
the designation (I) will appear to the left of the temperature value. The letter
“I” signifies that the primary air temperature value was measured Internally.
For example:
T-AIR 86.5 °F (I)